CYCO recently delivered a complete dust suppression system for a construction site in Taiwan. The project combines fog columns and 40 m fog cannons to provide continuous area coverage and targeted dust control across an outdoor working environment.
By combining two complementary dust suppression systems, the solution addresses both widespread background dust and concentrated dust generated by specific construction activities.
Table of Contents
1. Project Overview
Outdoor construction sites can have multiple dust sources operating at the same time. Earth excavation, material handling, vehicle loading and unloading, and temporary material storage can all contribute to airborne dust.
For this Taiwan project, CYCO developed a combined solution using two-arm fog columns and 40 m fog cannons.
The system was designed around two main objectives:
- Provide continuous dust suppression across the wider site
- Deliver targeted suppression to areas with higher dust emissions
This combination allows the dust suppression equipment to adapt to different working conditions across the construction site.
Project Configuration at a Glance
Item | Project Specification |
Project Location | Taiwan |
Application | Construction Site Dust Suppression |
Dust Suppression System | Fog Columns + Fog Cannons |
Fog Cannon Model | TWCYWP-40 |
Fog Cannon Quantity | 2 Units |
Fog Cannon Spray Range | Approx. 40 m |
Fog Cannon Droplet Size | ≤150 μm |
Working Pressure | ≥15 bar |
Water Consumption | Approx. 2 m³/h per unit |
Total Power | Approx. 11 kW per unit |
Nozzles | 40 pcs per unit |
Fog Column Spray Coverage | Approx. 15 m |
Fog Column Installation Spacing | Approx. 30 m |
2. CYCO Dust Suppression Solution
CYCO combined two complementary dust suppression technologies for the project:
Equipment | Quantity | Main Function |
Two-arm fog columns | Multiple units | Continuous area dust suppression |
40 m fog cannons | 2 units | Targeted dust suppression |
Fog Columns
The fog columns were installed across the site to provide continuous background dust suppression.
Each column has two groups of spray nozzles, with about 15 m of spray coverage per nozzle group. The planned installation spacing was approximately 30 m between units.
TWCYWP-40 Fog Cannons
Two TWCYWP-40 fixed fog cannons were deployed for targeted dust suppression.
With an approximate 40 m spray range, the fog cannons deliver atomized water mist to areas with more concentrated dust generation.
The fog columns provide ongoing coverage across the site, while the fog cannons can be directed toward high-dust areas when additional suppression is required. This combination creates a practical area coverage + targeted suppression strategy.
3. Fog Columns for Continuous Area Coverage
The fog columns provide the project’s continuous dust suppression function.
Each vertical column carries two groups of spray nozzles, providing approximately 15 m spray coverage for each nozzle group. The columns were arranged at approximately 30 m intervals according to the site deployment plan.
This arrangement helps provide overlapping coverage across the working area and reduce untreated areas between individual units.
The vertical design also helps keep the equipment clear of major construction traffic routes. Precast concrete bases provide a stable foundation and simplify installation in the outdoor working environment.
The fog columns can provide regular misting during normal construction activities, helping maintain continuous background dust control across the site.
4. Fog Cannons for Targeted Dust Control
Two TWCYWP-40 fog cannons were supplied for areas with higher or more concentrated dust emissions.
The fog cannons were intended for applications such as:
- Earth excavation
- Vehicle loading and unloading
- Material handling
- Other temporary or concentrated dust-generating activities
With a spray range of approximately 40 m, the fog cannons provide long-range misting and can be directed toward specific dust sources.
TWCYWP-40 Specifications
Each project fog cannon is equipped with 40 nozzles and produces droplets of ≤150 μm.
Key specifications include:
- Model: TWCYWP-40
- Spray range: Approx. 40 m
- Droplet size: ≤150 μm
- Working pressure: ≥15 bar
- Water consumption: Approx. 2 m³/h
- Total power: Approx. 11 kW
- Nozzle quantity: 40 pcs
The actual equipment specification plate from this project provides the model and operating specifications shown above.
5. Fog Cannon vs. Fog Column
| Â | Fog Cannon | Fog Column |
Main Role | Targeted dust suppression | Continuous area coverage |
Coverage | Long-range, approx. 40 m | Approx. 15 m per nozzle group |
Best For | High-dust points | General site coverage |
Typical Applications | Excavation, loading, unloading | Continuous background dust control |
Operation | Targeted / adjustable | Fixed-position coverage |
For this Taiwan project, CYCO combined both systems to provide continuous site coverage while allowing additional suppression at high-dust locations.
6. How the Two Systems Work Together
The main feature of this project is the combination of continuous area coverage and targeted dust suppression.
Fog Columns
Continuous background coverage
↓
Wider site dust suppression
40 m Fog Cannons
Targeted long-range spraying
↓
High-dust area suppression
Together, the two systems provide a more flexible approach to outdoor dust control.
The fog columns can operate as the site’s regular dust suppression system, while the fog cannons can be used when excavation, loading, unloading, or other activities create concentrated dust emissions.
This area coverage + point-source suppression strategy is well suited to construction sites, earthwork projects, aggregate yards, and other large outdoor environments where dust sources can vary throughout the day.
7. Project Installation and Deployment
The dust suppression equipment was deployed according to the working conditions and coverage requirements of the construction site.
The fog columns were arranged at approximately 30 m intervals to provide continuous coverage, while the two 40 m fog cannons were positioned to target key dust-generating areas.
The fog column design uses precast concrete bases, helping provide stable installation without taking up significant construction traffic space.
The system also supports remote control, allowing operators to manage the equipment according to site conditions and operating requirements.
8. CYCO Dust Suppression System in Action
The Taiwan project shows how a combination of fixed and long-range dust suppression equipment can be deployed in a real outdoor construction environment.
The fog columns provide continuous site coverage, while the TWCYWP-40 fog cannons provide additional long-range suppression for areas with concentrated dust emissions.
Project Highlights
- Taiwan construction site dust suppression project
- Fog columns + 40 m fog cannons combined in one system
- Two TWCYWP-40 fog cannons deployed
- Approx. 40 m fog cannon spray range
- ≤150 μm fog cannon droplet size
- ≥15 bar working pressure
- Approx. 2 m³/h water consumption per fog cannon
- Approx. 11 kW total power per fog cannon
- 40 nozzles per TWCYWP-40 unit
- Approx. 15 m spray coverage for each fog column nozzle group
- Approx. 30 m fog column installation spacing
- Remote control capability
- Designed for outdoor construction applications
9. From System Planning to Project Delivery
This Taiwan project demonstrates CYCO’s ability to provide a complete dust suppression solution rather than supplying individual equipment only.
From system planning and equipment manufacturing to cross-regional delivery and project deployment, CYCO supports customers with dust suppression solutions based on their site layout, dust sources, coverage requirements, and operating conditions.
By combining fog columns with long-range fog cannons, CYCO can develop flexible dust control solutions for construction sites and other large outdoor environments.
10. Need a Dust Suppression Solution for Your Site?
If your project requires continuous area coverage, targeted dust suppression, or a combination of different spraying systems, CYCO can help develop a solution based on your application requirements.
Contact CYCO to discuss your dust suppression project.